Publikasi Scopus FKUI 2021 per tanggal 30 Juni 2021 (428 artikel)

Pranata R., Yonas E., Vania R., Sidipratomo P., July J.
57201973901;57201987097;57208328436;55674568400;24080082500;
Efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm—A systematic review and meta-analysis
2021
Interventional Neuroradiology
27
1
60
67
2
Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia; Faculty of Medicine, Universitas YARSI, Jakarta, Indonesia; Department of Radiology, Faculty of Medicine, Universitas Indonesia, Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia; Department of Neurosurgery, Medical Faculty, Pelita Harapan University, Tangerang, Indonesia; Neuroscience Centre Siloam Hospital, Tangerang, Indonesia
Pranata, R., Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia; Yonas, E., Faculty of Medicine, Universitas YARSI, Jakarta, Indonesia; Vania, R., Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia; Sidipratomo, P., Department of Radiology, Faculty of Medicine, Universitas Indonesia, Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia; July, J., Department of Neurosurgery, Medical Faculty, Pelita Harapan University, Tangerang, Indonesia, Neuroscience Centre Siloam Hospital, Tangerang, Indonesia
Objective: PulseRider is a novel self-expanding nickel-titanium (nitinol) stent for treatment of wide-necked aneurysms, which is commonly located at the arterial branches in the brain. This systematic review and meta-analysis aims to assess the efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm. Method: We performed a systematic literature search on articles that evaluate the efficacy and safety of PulseRider-assisted coiling of the wide-necked aneurysm from several electronic databases. The primary endpoint was adequate occlusion, defined as Raymond-Roy Class I + Raymond-Roy Class II upon immediate angiography and at six-month follow-up. Results: There were a total of 157 subjects from six studies. The rate of adequate occlusion on immediate angiography was 90% (95% CI, 85%–94%) and 91% (95% CI, 85%–96%) at six-month follow-up. Of these, Raymond-Roy Class I can be observed in 48% (95% CI, 41%–56%) of aneurysms immediately after coiling, and 64% (95% CI, 55%–72%) of aneurysms on six-month follow-up. Raymond-Roy Class II was found in 30% (95% CI, 23%–37%) of aneurysms immediately after coiling, and 25% (17–33) after six-month follow-up. Complications occur in 5% (95% CI, 1%–8%) of the patients. There were three intraoperative aneurysm rupture, three thrombus formation, three procedure-related posterior cerebral artery strokes, one vessel dissection, and one delayed device thrombosis. There was no procedure/device-related death. Conclusions: PulseRider-assisted coiling for treatment of patients with wide-necked aneurysm reached 90% adequate occlusion rate that rises up to 91% at sixth month with 5% complication rate. © The Author(s) 2020.
Coiling; endovascular; intracranial aneurysm; PulseRider; wide-necked aneurysm
antithrombocytic agent; adult; aneurysm rupture; angiography; arterial spin labeling; Article; blood clotting; cerebral artery disease; coil embolization; comparative effectiveness; dissection; drug safety; female; human; intracranial aneurysm; magnetic resonance angiography; male; metastasis; nuclear magnetic resonance imaging; occlusion; systematic review; thrombosis
SAGE Publications Inc.
15910199
32635777
Article
Q2
740
6528