Efficacy of Sternum Guard vs. bone wax in post-cardiac surgery patients: a randomized controlled trial
2024
Journal of Cardiovascular Surgery
65
6
539
545
6
1
Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia; Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Division of Pediatric and Congenital Heart Surgery, National Cardiovascular Center, Jakarta, Indonesia
Hanafy D.A., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Muroso K.K., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia; Sugisman S., Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Soetisna T.W., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Tjubandi A., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Wartono D.A., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Herlambang B., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Adult Cardiac Surgery, National Cardiovascular Center Harapan Kita, West Jakarta, Indonesia; Busro P.W., Division of Cardiac, Thoracic and Vascular Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia, Division of Pediatric and Congenital Heart Surgery, National Cardiovascular Center, Jakarta, Indonesia
BACKGROUND: Median sternotomy offers the main access during cardiac surgery. However, a surgical site infection (SSI) of the sternum is a distressing complication following this procedure. The incidence of postoperative superficial and deep SSI in cardiac surgery varies from 1.3% to 12.8%. Bone wax, a nonabsorbable substance applied as a mechanical barrier following a median sternotomy, can increase the risk of postoperative sternal dehiscence. Sternum Guard (Vygon, Ecouen, France), a sternal protection device used to cover the sternum after a median sternotomy, offers mechanical protection to prevent lesions on the sternum. The aim of this study was to compare the effectiveness of Sternum Guard (Vygon) and bone wax in reducing SSI and facilitating hemostasis in post-cardiac surgery patients. METHODS: This single-blinded, single center randomized controlled trial comprised 414 adult patients who underwent cardiac surgery. The postoperative outcomes assessed were SSI and the quantity of blood lost from the sternal edges in the Sternum Guard (Vygon; treatment) and bone wax (control) groups. RESULTS: The superficial SSI prevalence in the Sternum Guard group was lower than that in the bone wax group (2.9% vs. 8.2%, respectively; P=0.018). The incidence of deep SSI was also lower in the Sternum Guard group (1%) compared to the control group (2.9%) although this was not statistically significant (P=0.284). In terms of intraoperative sternal bleeding, Sternum Guard (Vygon) absorbed more than the sterile drapes used in the control group (84.97±115.99 vs. 81.18±14.62, respectively; P=0.012). CONCLUSIONS: Sternum Guard (Vygon) had a significantly lower incidence of postoperative infection and bleeding from the sternum compared to bone wax. © 2024 THE AUTHORS.
Cellulose; Infections; Thoracic surgery
Aged; Cardiac Surgical Procedures; Female; Hemostatics; Humans; Male; Middle Aged; Palmitates; Risk Factors; Single-Blind Method; Sternotomy; Sternum; Surgical Wound Dehiscence; Surgical Wound Infection; Treatment Outcome; Waxes; bone wax; bone wax; hemostatic agent; palmitic acid; wax; adult; aortic valve repair; Article; bleeding; cardiopulmonary bypass; controlled study; coronary artery bypass graft; diabetes mellitus; female; heart surgery; hemostasis; hospitalization; human; hypertension; major clinical study; male; middle aged; postoperative infection; randomized controlled trial; sternotomy; surgical infection; adverse event; aged; comparative study; epidemiology; etiology; prevention and control; risk factor; single blind procedure; sternotomy; sternum; surgery; surgical infection;