Intraocular pressure measurements in paediatric glaucoma: A narrative review on accuracy, tolerability, and ease of use
2024
Medical Journal of Malaysia
79
2
206
211
5
0
Department of Ophthalmology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia; Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia
Yulia D.E., Department of Ophthalmology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia; Tan S., Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia
Introduction: Numerous tonometers are available to measure intraocular pressure (IOP) in children with glaucoma. This review aims to discuss IOP measurement techniques and principles and compare the accuracy, tolerability and ease of use of available tonometers in measuring IOP in paediatric glaucoma patients. Materials and Methods: A review of observational studies was conducted to discuss the accuracy, tolerability and ease of use of tonometers in measuring IOP in children with glaucoma. Results: Goldmann applanation tonometry (GAT) and its portable handheld versions remain the gold standard in measuring IOP. Tono-Pen (Reichert Ophthalmic Instruments, Depew, New York, USA) and rebound tonometer (RBT) both correlate well with GAT. Although both tonometers tend to overestimate IOP, Tono-Pen overestimates more than RBT. Overestimation is more remarkable in higher IOP and corneal pathologies (such as but not limited to scarred cornea and denser corneal opacity). RBT was better tolerated than other tonometers in children and was easier to use in children of all ages. Conclusions: RBT is the preferred tonometer for measuring IOP in children with glaucoma, as it is less traumatic, time efficient and does not require fluorescein dye or anaesthesia. However, examiners should use a second tonometer to confirm elevated IOP readings from the RBT. © 2024, Malaysian Medical Association. All rights reserved.
glaucoma; Intraocular pressure; measurement; paediatric; tonometry
Child; Cornea; Glaucoma; Humans; Intraocular Pressure; Manometry; Reproducibility of Results; Tonometry, Ocular; child; cornea; glaucoma; human; intraocular pressure; manometry; oculoplethysmography; procedures; reproducibility