Publikasi Scopus 2010 s/d 2022

Putu Inten Gayatri I.A., Handika A.D., Wibowo W.E., Fitriandini A., Fadli M., Yudi Putranto A.M., Yudhi Prasada D.N., Okselia A., Suharsono, Pawiro S.A.
57852262700;57852262800;36476700000;57189514406;55866941300;57851841800;57851411700;57852262900;57851841900;35776824000;
2-Dimensional IMRT dose audit: An Indonesian multicenter study
2022
Applied Radiation and Isotopes
188
110415
1
Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia; Department of Radiation Oncology, Persahabatan General Hospital, Jakarta, Indonesia; Department of Radiation Oncology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo General Hospital, Jakarta, Indonesia; Department of Radiation Oncology, MRCCC Siloam Hospitals, Jakarta, Indonesia; Department of Radiation Oncology, Hasan Sadikin General Hospital, Bandung, Indonesia; Department of Radiotherapy, Dharmais National Cancer Center Hospital, Jakarta, Indonesia
Putu Inten Gayatri, I.A., Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia, Department of Radiation Oncology, MRCCC Siloam Hospitals, Jakarta, Indonesia; Handika, A.D., Department of Radiation Oncology, Persahabatan General Hospital, Jakarta, Indonesia; Wibowo, W.E., Department of Radiation Oncology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo General Hospital, Jakarta, Indonesia; Fitriandini, A., Department of Radiation Oncology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo General Hospital, Jakarta, Indonesia; Fadli, M., Department of Radiation Oncology, MRCCC Siloam Hospitals, Jakarta, Indonesia; Yudi Putranto, A.M., Department of Radiation Oncology, MRCCC Siloam Hospitals, Jakarta, Indonesia; Yudhi Prasada, D.N., Department of Radiation Oncology, MRCCC Siloam Hospitals, Jakarta, Indonesia; Okselia, A., Department of Radiation Oncology, Hasan Sadikin General Hospital, Bandung, Indonesia; Suharsono, Department of Radiotherapy, Dharmais National Cancer Center Hospital, Jakarta, Indonesia; Pawiro, S.A., Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia
Intensity modulated radiation therapy (IMRT) is an advanced technique in radiation therapy delivery. IMRT depends on the accuracy of the multileaf collimator during treatment. Hence, the actual dose distribution can deviate from the treatment planning system's calculation. This study aimed to perform a multicentre planar dosimetry audit of radiotherapy centres in Indonesia, using the structure sets from AAPM TG-119. The gamma index used to evaluate the dose distribution was 3%/3 mm and 3%/2 mm. We observed 100% gamma index passing rates mostly in the 3%/3 mm evaluations. The gamma index passing rates dropped in the 3%/2 mm analysis. Most of the radiotherapy centres participating in this audit satisfied each criterion's tolerance limit of the action level. This study may become a first result for the next multicenter IMRT audit by using a standardized protocol. © 2022 Elsevier Ltd
AAPM TG-119; Dose audit; Gamma index analysis; IMRT; Passing rate
Dosimetry; Radiation; 2 - Dimensional; AAPM TG-119; Dose audit; Dose distributions; Gamma index analyse; Gamma indices; Index analysis; Intensity-modulated radiation therapy; Multi-centre study; Passing rate; Radiotherapy; article; dosimetry; human; Indonesia; multicenter study; radiation dose distribution; radiotherapy; clinical trial; intensity modulated radiation therapy; procedures; radiometry; radiotherapy dosage; radiotherapy planning system; Indonesia; Radiometry; Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted; Radiotherapy, Intensity-Modulated
Universitas Indonesia
This study was supported by PUTI research grant Universitas Indonesia with contract number NKB-951/UN2.RST/HKP.05.00/2020. The authors would like to thank the Department of Radiation Oncology, Persahabatan National General Hospital; Department of Radiation Oncology, Faculty of Medicine, Universitas Indonesia, dr. Cipto Mangunkusumo Hospital; Department of Radiation Oncology, MRCCC Siloam Hospitals
Elsevier Ltd
09698043
36027871
Article
Q3
422
11587